  • Current Rating: 12A
  • Model: KDRA28L
  • Mounting Style: Chassis
  • All returns accepted: ReturnsNotAccepted
  • Country/Region of Manufacture: United States
  • Number of Phases: 3
  • Brand: TCI
  • MPN: KDRA28L
  • Voltage Rating: 600
  • Condition: Brand new without original box. May have some nicks scrapes or chips in plastic parts from being jostled around together.

    Description

    ONE BRAND NEW UNUSED TCI KDRA28L
    3 PHASE
    KDR LINE DRIVE REACTOR 12A 600V 50/60Hz 3HP
    EQUIVALENT TO MTE RL-01201 AND HAMMOND RM0012N13
    MOTOR AMPS 10.6
    PLEASE SEE THE SPEC DATA SHEET BELOW FOR THIS PART
    PLEASE KNOW WHAT YOU ARE BUYING!
    COPY AND PASTE:
    http://www.electricmotorwholesale.com/TCI-KDRA28L.html
    YOU MAY FIND SOME NICKS OR SCRATCHES OR EVEN A CHIP IN A PLASTIC PART FROM BEING ALL TOGETHER IN A BIG BOX
    BRAND NEW AND NEVER USED!
    Reduction of nuisance tripping caused by:
    Transient voltages caused by capacitor switching
    Line notching
    DC bus over-voltage tripping
    Inverter over-current and over-voltage
    Additional benefits include:
    Lowering injected percentage of harmonic current
    Improving true power factor
    Reducing cross-talk between drives
    Adding impedance to drives with DC link chokes/reactors when more impedance is desired due to a relatively stiff source
    TCI KDR Line Reactors
    reduce harmonic current, Increases life of drive and Protects sensitive equipment.
    Harmonics and Power Quality Stabilization:
    Variable frequency drives are beneficial to a wide range of applications, but contain a power conversion process that creates current and voltage distortion which can cause system-wide problems, including:
    Transformer and distribution equipment overheating
    Random breaker tripping
    Sensitive equipment may fail completely
    Poor power factor
    Reduced system efficiency
    The addition of a KDR Reactor will reduce harmonic content, which reduces the total RMS current, thereby improving the total power factor.
    Nuisance tripping is less common
    Drive uptime is increased
    Power factor is improved
    A voltage transient, commonly caused by capacitor bank switching (or other issues), sends a current surge into the VFD bus capacitor. The additional current raises bus voltage, thus causing a drive fault (trip). In addition, this overvoltage condition will cause the drive to shut down in order to protect its components.
    Unbalanced Distribution Systems cause Nuisance Tripping
    : Input voltage phase unbalance may prevent the drive from performing due to subsequent over-current conditions which cause the drive to cease operating. KDR Optimized Line Reactor on Unbalanced systems The addition of a KDR Reactor to the input of every drive will help balance the drive input line currents.
    PLEASE SEE THE PICTURES AND I ALWAYS TRY MY BEST AT AN HONEST DESCRIPTION, PLEASE ASK ANY QUESTIONS BEFORE BIDDING OR BUYING!
    YOURS TO ENJOY, NEEDS A GOOD HOME!
    IF THERE IS EVER ANY MEANINGFUL SHIPPING OVERAGE IN YOUR FAVOR I ALWAYS REFUND IT.
    CHEAP FAST SHIPPING RIGHT TO YOUR DOORSTEP!
    I ALWAYS SEND DATED SHIPPING CONFIRMATION E-MAILS!
    WINNER PAYS ACTUAL SHIPPING, DETERMINED BY THE EBAY SHIPPING CALCULATOR
    CLEARED PAYPAL PAYMENTS ALLOW ME TO SHIP THE NEXT POSTAL MORNING, NO DELAY. I SHIP EVERYTHING NEXT POSTAL MORNING AFTER PAYMENT!
    PLEASE SEE MY OTHER AUCTIONS!
    Click here!
    NEW ITEMS EVERY OTHER DAY!
    THANKS FOR LOOKING!
    *****